Solar Thermal Fluids

Solaris is Hydratech’s range of glycol antifreeze heat transfer fluids for solar thermal hot-water systems: evacuated tube, flat plate and thermodynamic panels. Every Solaris fluid is non-toxic and contains reversibly evaporable inhibitors built for the high temperatures inside solar collectors. Choose a ready-mixed fluid to pour straight in, or a concentrate to dilute yourself.

Evacuated tube, flat plate & thermodynamic panelsReady-mixed or concentrateAll four fluids non-toxicMeets BS6580 & ASTM D13843+ year shelf life, sealed

Compare the Solaris range

FluidSupplied asSummaryEfficiencyAntifreezeCorrosion controlToxicityFrost protection
Solaris DTX20Detoxified ethylene glycol · non-toxicReady-mixedABAAA−20°CBuy
Solaris PG20Propylene glycol · non-toxicReady-mixedBCBAA−20°CBuy
Solaris DTXDetoxified ethylene glycol · non-toxicConcentrateABAAATo −50°CBuy
Solaris PGCPropylene glycol · non-toxicConcentrateBCCAATo −50°CBuy

Ratings are Hydratech’s own, from A (best) to E. Concentrates protect down to −50°C depending on how much you add.

Ready-mixed or concentrate? Read our solar fluid guide: the Solaris fluids compared, mixing rates, and how to fill or top up a solar system.

Which Solaris do I need?

Solaris DTX20: ready-mixed

Pour straight in, no mixing. Frost protection to −20°C. Hydratech’s non-toxic detoxified ethylene glycol, rated higher for efficiency and antifreeze than propylene glycol.

Solaris PG20: ready-mixed

Ready-to-use propylene glycol with frost protection to −20°C. Runs efficiently at 170°C for long periods and withstands 200°C for short periods.

Solaris DTX: concentrate

Mix it yourself to the protection you need. Hydratech’s minimum dose for solar systems is 35% of system volume, and normally no more than 45%.

Solaris PGC: concentrate

Propylene glycol concentrate. Its inhibitors withstand stagnation temperatures of 300°C. 30% gives −13°C and 50% gives −31°C.

Mixing a concentrate

Work out the total system volume and add concentrate for the lowest temperature you need. Dilute with deionised, distilled or ultrapure water, and avoid water high in calcium salts or chlorides. Hydratech recommends checking the strength with a recently calibrated refractometer.

Solaris DTXFrost protection
38%−25°C
42%−30°C
Solaris PGCFrost protection
30%−13°C
35%−17°C
40%−21°C
45%−26°C
50%−31°C

Concentrate as a % of total system volume, from Hydratech’s data sheets. For Solaris DTX in solar systems, Hydratech specifies a minimum dose of 35% and normally no more than 45%.

Topping up? Hydratech’s instruction is to top up only with the same Solaris fluid that is already in the system. If you’re not sure what’s in it, contact us before adding anything.

Before filling, Hydratech advises that pipework should be clean and free of debris and biological contamination (BSRIA guide BG 29/2012), with air ingress kept to a minimum. A pressurised system is best.

Need 10L, 25L, 205L or an IBC?

We stock Solaris in 5 and 20 litre drums. Every Solaris fluid is also available in 10 and 25 litre drums, 205 litre drums and 1000 litre IBCs. Tell us what you need and we’ll come back with a price.

Ask for a price

Showing all 4 results

  • Hydratech Solaris DTX solar thermal fluid concentrate drum

    Hydratech Solaris DTX Solar Thermal Fluid Concentrate

    Price range: €65.00 through €199.00 inc Vat

    Non-toxic glycol antifreeze concentrate for high-temperature solar thermal systems. Dilute to the frost protection you need, down to −50°C.

    • Hydratech’s non-toxic detoxified ethylene glycol (DeTox™)
    • Minimum dose 35% of system volume in solar systems
    • Meets BS6580 & ASTM D1384 corrosion standards
    Select optionsLoading Done This product has multiple variants. The options may be chosen on the product page
  • Hydratech Solaris DTX20 ready-mixed solar thermal fluid drum

    Hydratech Solaris DTX20 Ready-Mixed Solar Thermal Fluid

    Price range: €32.00 through €95.00 inc Vat

    Ready-to-use non-toxic glycol heat transfer fluid for solar thermal hot-water systems. Pre-mixed for frost protection to −20°C, so it goes straight in with no diluting.

    • Hydratech’s non-toxic detoxified ethylene glycol (DeTox™)
    • For evacuated tube, flat plate and thermodynamic panels
    • Meets BS6580 & ASTM D1384 corrosion standards
    Select optionsLoading Done This product has multiple variants. The options may be chosen on the product page
  • Hydratech Solaris PGC propylene glycol solar fluid concentrate drum

    Hydratech Solaris PGC Propylene Glycol Solar Fluid Concentrate – 5L

    €89.00 inc Vat

    Non-toxic propylene glycol antifreeze concentrate for high-temperature solar thermal systems. Dilute to the frost protection you need, down to −50°C.

    • Runs at 170°C for prolonged periods, 200°C for short periods
    • Inhibitors withstand 300°C stagnation temperatures
    • 30% gives −13°C; 50% gives −31°C
  • Hydratech Solaris PG20 ready-mixed propylene glycol solar fluid drum

    Hydratech Solaris PG20 Ready-Mixed Propylene Glycol Solar Fluid

    Price range: €40.00 through €129.00 inc Vat

    Ready-to-use non-toxic propylene glycol heat transfer fluid for solar thermal hot-water systems. Pre-mixed for frost protection to −20°C.

    • Runs at 170°C for prolonged periods, 200°C for short periods
    • Inhibitors withstand 300°C stagnation temperatures
    • Meets BS6580 & ASTM D1384 corrosion standards
    Select optionsLoading Done This product has multiple variants. The options may be chosen on the product page